Hi-Therm PERT2Gen PERT Type II EVOH 16x2.0 pipe is A flexible three-layer PERT Type II pipe with EVOH oxygen barrier for water underfloor heating systems.

The EVOH oxygen barrier reduces oxygen diffusion into the heating circuit, helping protect metal components from corrosion and extending system service life.

  • Size: 16.0 x 2.0 mm.
  • Material: PERT Type II, heat-resistant polyethylene.
  • Oxygen barrier: EVOH, oxygen diffusion < 0.1 mg/dl.
  • Temperature: up to +70°C.
  • Coil length: 240 m or 500 m.
  • Made in: Spain. Warranty - 10 years.
Pipe and fitting specifications
Product type
Underfloor heating pipe
Material
PERT Type II, heat-resistant polyethylene
Size / diameter
16.0 x 2.0 mm
Pressure / operating class
Class 1/10 bar, 2/10 bar, 4/10 bar, 5/8 bar
Reinforcement / barrier
EVOH oxygen barrier; oxygen diffusion < 0.1 mg/dl
Operating temperature
Up to +70 °C
Application
Water underfloor heating systems
Standard
UNE EN ISO 22391; DIN 4726
Country of manufacture
Spain
Warranty
10 years

Hi-Therm PERT2Gen PERT Type II EVOH 16x2.0 pipe: specifications and installation

ParameterValue
Outside diameter / wall thickness16.0 mm / 2.0 mm
Pipe materialPERT Type II, heat-resistant polyethylene
Structure3 layers: polyethylene / adhesive layer / EVOH
Oxygen barrierEVOH, oxygen diffusion < 0.1 mg/dl
Application classes1/10 bar, 2/10 bar, 4/10 bar, 5/8 bar
Temperature rangeup to +70°C
Coil weight23.88 kg (240 m), 43.50 kg (500 m)
Coil length240 m or 500 m
StandardsISO 22391, DIN 4726
Made inSpain
Warranty10 years

Installation: installation should be carried out by qualified personnel at an ambient temperature of at least +10°C. Press fittings or compression fittings suitable for 2.0 mm wall thickness are recommended.

Before covering the underfloor heating circuit, hydraulic leak testing must be completed. During screed pouring, the pipe should remain under 0.3 MPa pressure; the minimum screed layer above the pipe is 3 cm.

Technical data is based on the Hi-Therm Pipe Spain 2025 catalog.